Displayed results

Microscope observation dish temperature control device O n p u - 4

The warm breeze envelops the observation dish, and the living cells feel like they're in a hot spring.

Since there is a correlation between the supply fan inlet temperature, culture medium temperature, and outlet temperature, this relationship formula will be determined during the performance tests of each unit conducted at the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship formula based on the supply fan inlet temperature and outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. As a result, a temperature setting error of ±1.0℃ or less has been achieved.

  • Temperature and Humidity Control

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Microscope Observation Plate Temperature Control Device Peltier-4

The warm breeze envelops the observation dish, and the living cells feel like they're in a hot spring.

There is a correlation between the supply fan inlet temperature, the culture medium temperature, and the outlet temperature. Therefore, this relationship formula will be determined during the performance tests conducted for each unit in the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship formula based on the supply fan inlet temperature and the outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. This has achieved a temperature setting error of ±1.0°C or less.

  • Other process controls